Coleman Hot Tub Error Codes

Posted onby admin

P6OVXVqO_Y/hqdefault.jpg' alt='Coleman Hot Tub Error Codes' title='Coleman Hot Tub Error Codes' />Spa Hot Tub Error Codes OH, OHH, OMGIn our series on spa and hot tub error codes, we turn our attention today to the HOT messages that your topside control may be trying to give you. OH, or OHH, or OHS Overheat all mean that a temperature sensor has detected unsafe water temperatures of 1. Coleman Lazy Spa Error CodesDIY Hot Tub Repair, keeping you in hot water is our goal Home. Sorry, the product was not found. Coleman Spa Manuals, Spa Parts for All Spa Brands, Spa Jets, Spa. Answers to common LayZSpa issues as well as advice and troubleshooting from the official home of LayZSpa. F, and your spa is in an emergency cool down mode, shutting off the heater, and turning on circulation pumps and blower to help dissipate heat. Open the spa cover to allow excess heat and steam to escape. The spa obviously should not be used when OH or OHH is flashing on the topside control as the water could be scalding hot for several more minutes. Kay Jamison Una Mente Inquieta Pdf Files on this page. Coleman Lay Z Spa TroubleshootingAfter the water cools, a high limit switch may be need to be reset on some spa packs look for a red reset button. Press any topside button to reset a digital spa after the water has cooled to 1. F. What causes a Spa to Overheat Low Water Flow LF, FLO, is the usual cause of an overheating OH, OHH spa or hot tub. When water doesnt flow fast enough through the heater, it removes less heat, and the temperature of the water increases. Eventually, the temp sensors or high limit switches will detect the increased water temperature and shut everything down. The causes of low water flow in a spa include Dirty spa filter cartridge. Closed or partially closed valves or jets. Pump has an air lock, or has lost prime. Coleman Hot Tub Error Codes' title='Coleman Hot Tub Error Codes' />Low water level in spa, skimmer sucking air. Spa drain cover is obstructed or pipe is blocked. What else causes a Spa to Overheat If your water flow is perfectly fine, then you could have a problem with the thermostat or high limit switches used on older spa packs, which could fall out of calibration, or become too sensitive. Digital spas have electronic sensor circuits, which are more durable than mechanical switches, however temperature sensors, hi limit sensors, relays and circuit boards also eventually fail on modern spas. In most cases, for newer spas anyway, the water flow problem can be quickly remedied and the spa will cool, reset and start again on its own. Some panels need a prompt from you to restart. For spas without digital controls, you may need to manually reset the high limit switch near the heater housing. Spa Overheating Troubleshooting Flow Chart. Heres a Cal Spa troubleshooting flow chart that has some other possible triggers of seeing OH, OHS, OHH or HH blinking on your spa panel. Open the spa cover and let the spa cool down for 1. OH, HH or HOT trouble codes, or a hot tub overheating is not usually a spa heater problem it is almost always a flow problem, and when its not a flow problem, its a bad temp sensor, high limit or a stuck relay. Heres another Cal Spa troubleshooting flowchart for spa error codes OH, including testing the spa heater elementfor excessive resistance, done with the spa heater and all systems powered Off, and only by someone qualified to test safely. So, the next time your spa throws you a OH, OHH or some other Overheat error code, you know what to do. Balboa Common Spa Topside Panel. Cyclic Redundancy Code CrC Checksum Error. The spa must be shut down. Quality spa parts company offering generic spa and hot tub replacement spa parts,spa packs and spa jets. This week we have a question from one of our hot tub customers about hot tub repair and the E6 or Error 6 on their hot tub top side control. The E6 error code on your. Coleman portable hot tub error codes Comments Off, Coleman Saluspa Hot Tub Best Thing I Have Bought. Aug 8th, 2017 by. Clean or replace the spa filter, open all the jets and turn the pump on high. If you still have problems, check over your temp sensor and hi limit circuits for wire or plug or sensor problems. Happy Hot TubbinDaniel Lara. Hot Tub Works. Tags spa error codes, Spa Heater Elements, spa heaters. This entry was posted. Tuesday, January 6th, 2. Consumer Research for Best Hot Tub, hottubworks. Spa Parts. You can follow any responses to this entry through the RSS 2. Both comments and pings are currently closed. Common Spa Side Error Codes. FLO, FL, FLC, FL1, PS, Blinking Lights Pressure Switch or Flow Switch Failure. The codes above are all related to flow issues or the pressure switchflow switch and are the most common error codes. These error codes can be caused for several different reasons. The main reason is water flow through the spa control system, if water is not flowing at a rate to satisfy the pressure switch, it will result in one of the error codes above. The first thing you want to do before doing anything else is shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter clean or replace or too many jets were closed off. Other issues that can cause these error codes is debris wrapped around the pump impeller, or one of the valves is not open up all the way. The most common valve the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open all the way, you may need to dismantle the fittings to look inside. The final problem could be the pressure switchflow switch itself. You can check the switch by performing the test below. Shut the power down, remove the two wires to the pressure switchflow switch, find some sort of wire to join the wires, but dont do it yet. Turn the power back on, you have five seconds to join the wires together, do not join them before you turn the power on. Once this is done check ACROSS the heater element post, you should have either 1. If the error code goes away and you are getting the proper voltage then replace the pressure switchflow switch. Also try it this way, Unplug the wires from the pressure switchflow switch, turn on the pump and then jump the wires. FINAL NOTE Most spas are equipped with pressure switches and can be found threaded into the stainless steel heater manifold. Flow switches are plumbed in line with the plumbing. You can also check the pressure switch or flow switch with a an Ohm meter. When the water is not flowing it should be OPEN, not CLOSED, if it is closed replace it. The Sims 3 Mansion And Garden Stuff Crack. OH, OHH, OHS, OHt, HL, Hi. Li, Sn. 2, Sn. 3, t. S, Ht, Blinking Lights Temperature Sensor Failure. The error codes above are related to a temperature sensor failure, overheat problems or a flow problem. If your spa is in fact overheating then it is caused by one of two things, either the temperature sensor is defective or the relays on the circuit board that operate the heater are stuck shut causing and over heat issue, in this case you would need to either replace or repair the circuit board. For information regarding repairs click here. If your spa is not overheating and you are getting the above error codes then a couple of things could be happening. Depending on where the temp sensor is mounted usually in the wall of the spa in a sensor mount, you could have a flow issue. Shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter clean or replace or too many jets were closed off. In most cases overheat issues are related to the relays on the circuit board, or the temp sensor has failed and will need to be replaced. NOTE Temperature sensors should be mounted in a sensor mount in the wall of the spa and not behind the shield on the heater manifold with the hi limit sensor. The temp sensor is the larger of the two silver bullets. FINAL NOTE Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. Both are secured with black plastic nut around the gray cable. If one of these sensors needs to be replaced BOTH should be replaced at the same time. See M7 Sensors here. SN, Sn. 1, Sn. 2 Sn. HL, E1, E3, Prh, Ht. S, Blinking Lights. Hi Limit Sensor Failure. These error codes are similar to the ones previous, however we will be looking at these at another angle. Once again these can be caused by a flow issue. The first thing you want to do before doing anything else is shut the spa down, remove the filter and make sure all the jets are open. Then power the system back up, if the error code goes away, the problem was either a dirty filter clean or replace or too many jets were closed off. Other issues that can cause these error codes is debris wrapped around the pump impeller, or one of the valves is not open up all the way. The most common valve the tee handle valve, will show that the handle is up, but in many cases the gate is still half closed, make sure that it is open all the way, you may need to dismantle the fittings to look inside. At the same time this test is being done, put your hand on the stainless steel heater manifold, it should NOT be hot, it should only be at the same temperature the water in the spa is. If it is hot you have a flow issue, or if it stays hot after the pump is shut off either the pressure switch has stuck close see FLO error codes above or the relays on the board have stuck shut sending continuous power to the heater. If all these test are checked and they did not solve the error code issues, then it is possible you have a defective hi limit sensor. NOTE The Hi Limit Sensor is located behind a shield on the stainless heater manifold and is the smaller of the two silver bullets. See picture below for reference. FINAL NOTE Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. Both are secured with black plastic nut around the gray cable. If one of these sensors needs to be replaced BOTH should be replaced at the same time. See M7 Sensors here.